David Clark pointed out an error in my posting.  
I SHOULD have said:



According to the OSM/EE list of decisions dated
9/99...

Varistors between the mains and the protective
earth cannot be accepted by the following 
countries:

    Pluggable equipment, Type A:  Austria, Belgium,
    Denmark, Finland, Norway, Sweden, United Kingdom.


Varistors between the mains and the protective 
earth can be accepted by the following countries:

    Permanently connected equipment connected to 
    Protective Earth:  All countries.


Sorry for any confusion.