David Clark pointed out an error in my posting.
I SHOULD have said:
According to the OSM/EE list of decisions dated
9/99...
Varistors between the mains and the protective
earth cannot be accepted by the following
countries:
Pluggable equipment, Type A: Austria, Belgium,
Denmark, Finland, Norway, Sweden, United Kingdom.
Varistors between the mains and the protective
earth can be accepted by the following countries:
Permanently connected equipment connected to
Protective Earth: All countries.
Sorry for any confusion.
Best regards,
Rich
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
To cancel your subscription, send mail to:
majord...@ieee.org
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Jim Bacher: jim_bac...@mail.monarch.com
Michael Garretson: pstc_ad...@garretson.org
For policy questions, send mail to:
Richard Nute: ri...@ieee.org