Mike, Back in my days as Compliance Engineer for AT&T Global Information Solutions (NCR), I was successful in obtaining UL/CSA waiver for production line hipot testing of the end product on the basis of using a listed power supply that had already been subjected to hipot as a part of the power supply manufacturing process. Hipot was still required as a part of the UL/CSA evaluation for initial listing of the end product.
Ground continuity testing was still required due to the fact that the mounting of the power supply in the end product established necessary contacts for ground continuity. ----- Original Message ----- From: Mike Morrow <mi...@ucentric.com> To: EMC Society <emc-p...@majordomo.ieee.org> Sent: Thursday, August 31, 2000 1:40 PM Subject: Why routine hipot is required. > > I've been asked why a routine hipot test is required on an end assembly > computer when it uses a Listed power supply that has already been hipot > tested. So far I don't like the way I've worded my response. Basically > what I've said is that a power supply is approved as a component. The end > safety of the device depends on the installation. > > Can anyone add some more beef to this statement. Thanks. > > Mike Morrow > Senior Compliance Engineer > Ucentric Systems > 978-897-6482 > mi...@ucentric.com > www.ucentric.com > > > ------------------------------------------- > This message is from the IEEE EMC Society Product Safety > Technical Committee emc-pstc discussion list. > > To cancel your subscription, send mail to: > majord...@ieee.org > with the single line: > unsubscribe emc-pstc > > For help, send mail to the list administrators: > Jim Bacher: jim_bac...@mail.monarch.com > Michael Garretson: pstc_ad...@garretson.org > > For policy questions, send mail to: > Richard Nute: ri...@ieee.org > > ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org