No but there have been several companies in the UK that were closed down by
Enforcement Offices until they corrected Safety and EMC defects that they
were discovered. Another company voluntarily ceased production for 6v months
whilst tooling was modified.

Best regards

Gregg



Gregg Kervill DipIM, MIMgt, MIEEE

VP Engineering
Test4Safety.com Inc
PO Box 310,
Reedville, VA
22539. USA

Phone  ( 804) 453-3141
Fax        (804) 453-9039



------Original Message-----
-From: [email protected]
-[mailto:[email protected]]On Behalf Of John Juhasz
-Sent: Tuesday, June 11, 2002 8:31 AM
-To: 'Gonzalez, Kenneth P (Rocky)'
-Cc: [email protected]
-Subject: RE: DOC "Assembled from tested components"
-
-
-
-Rocky,
-
-While your message indicates that the FCC may not have a problem
-with the 'assembled from tested components' concept, it does not
-mean that the end-product will actually meet the limits.
-Poor routing of internal cables, insufficient grounding, just to
-mention a couple of items, can cause failures. This is why
-the EC doesn't have faith CE + CE = CE.
-Although it may work in some cases, it doesn't compare to
-actual testing. If you're going to 'mass produce' a particular
-configuration, take some time and check the emissions.
-You might surprised what you find. In the long run it doesn't
-pay to be 'dollar wise and pound foolish'.
-
-Just my opinion.
-
-GE Interlogix
-
-John A. Juhasz
-Fiber Options Div.
-Bohemia, NY
-
-
-
-> All,
->         Has anyone successfully issued a DOC using the
-"assembled from
-tested components" method for a personal computer?  I have not
-been able to
-find a floppy disk drive manufacturer that has any DOC
-documentation for
-their device; even the ones marketing directly to home users.
-Have I just
-not found the right manufacturer?
->
-> Best regards,
->
-> Rocky
->   -)-(-
->
-> Kenneth P. Gonzalez (Rocky)
-> Intergraph Solutions Group
-> Integrated Products Division
-> 170 Graphics Drive
-> Madison, Alabama, USA 35758
-> phone (256) 730-2131
-> fax      (256)730-2424
-> [email protected]
-
--------------------------------------------
-This message is from the IEEE EMC Society Product Safety
-Technical Committee emc-pstc discussion list.
-
-Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/
-
-To cancel your subscription, send mail to:
-     [email protected]
-with the single line:
-     unsubscribe emc-pstc
-
-For help, send mail to the list administrators:
-     Ron Pickard:              [email protected]
-     Dave Heald:               [email protected]
-
-For policy questions, send mail to:
-     Richard Nute:           [email protected]
-     Jim Bacher:             [email protected]
-
-All emc-pstc postings are archived and searchable on the web at:
-    http://ieeepstc.mindcruiser.com/
-    Click on "browse" and then "emc-pstc mailing list"
-


-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    http://ieeepstc.mindcruiser.com/
    Click on "browse" and then "emc-pstc mailing list"

Reply via email to