Other than they are both EMC test requirements, the difference is night and
day.  The MIL-STD-461 tests are:

Much more severe/sensitive
Cover much wider frequency bands
Are typically done with different equipment.  The MIL Radiated Immunity
tests use 8 different antennas, EN61326-1 uses 1.

The best thing to do is look at the applicable test requirements table in
the MIL-STD and compare to EN61326-1.  Products designed to the MIL-STD with
look very much different than one that just meets the EN.

Darrell Locke
Advanced Input Devices

-----Original Message-----
From: paul.j.sm...@teradyne.com [mailto:paul.j.sm...@teradyne.com]
Sent: Monday, November 25, 2002 8:23 AM
To: emc-p...@majordomo.ieee.org
Subject: RE: test requirements of MIL-STD -461 vs EN61326-1.






      Folks,

      We have received an inquiry, concerning on the key differences
      between the test requirements of
      MIL-STD -461 and EN61326-1.

      Can someone familiar with these two stds provide some details on
      these different test requirements.

      Your input would be most appreciated .

     Best Regards,            Paul J Smith
                    Teradyne, Inc.,      Boston


-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               davehe...@attbi.com

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

All emc-pstc postings are archived and searchable on the web at:
    http://ieeepstc.mindcruiser.com/
    Click on "browse" and then "emc-pstc mailing list"

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               davehe...@attbi.com

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

All emc-pstc postings are archived and searchable on the web at:
    http://ieeepstc.mindcruiser.com/
    Click on "browse" and then "emc-pstc mailing list"

Reply via email to