Hi Leslie,

some answers:
 Is this called compliance testing or engineering verification?"
Anything that has to do with product quality (like EMI) needs to be
addressed in terms
of engineering.

"Can we do this and declare compliance?"

Sure you can declare compliance, as the European System is simply not
targeted to complying with standards,
but to complying with "essential requirements". Of course you cannot declare
compliance with
the standard (to the letter).

Using standards is just a way to presumption of compliance. Art 10.1 EMCD
If you really DO deviate from the standard , you will need
to follow the TCF route using a Competent Body to show  compliance. Art 10.2
EMCD

Any deviation of the standard is doomed to art 10.2 , but changing an
undefined dwell
time to better meet the intention of the standard won't lead to a law suite.

Several product type of standards do address  the topic of dwell time btw.

One never can get condamned by not following the prescriptions of the EMCD
or standard, only
by creating to much EMI or lacking susceptability (and other essential
phenomenae).

Gert Gremmen
ce-test
  -----Original Message-----
  From: Leslie Bai [mailto:leslie_...@yahoo.com]
  Sent: donderdag 3 oktober 2002 21:37
  To: Gert Gremmen; paul_sc...@mitel.com; emc-p...@majordomo.ieee.org
  Subject: RE: Dwell time for Immunity under EN55024?


   Gert Gremmen wrote:

    ".......
    prescan with Increase frequency step size ! (watch out for resonances)
    Modify equipment to decrease fault response time (low pass filters ;
    software )
    Build Specifc test features
    Write specific test software
    ....."


    "I am wondering whoelse out there doing these - Is that not sufficient
to demonstrate conformity by follwoing standard procedures? What specific
test features, what specific test software, are they specifed in the
standards? Is this called compliance testing or engineering verification?"


    "Of course you will be violating the standard;"

    "Can we do this and declare compliance?"

    Leslie Bai

    NARTE Certified Engineer

    (EMC-002112-NE)

    www.siemic.com







----------------------------------------------------------------------------
--
  Do you Yahoo!?
  New DSL Internet Access from SBC & Yahoo!