Hi Ken,

Only the maximum reading over the scan height is used.  The received signal
is nominally the vector sum of the line of sight path and the reflected or
"image" path from the ground plane.  In horizontal polarization there is
also 180 degree phase shift due to conservation of charge physics with the
ground plane.

Best regards,

Brent DeWitt