Hello Group, I have some concerns regarding Ethernet circuit design and applicable Hipot testing. If you have your typical 10/100 interface, you would have your RJ45 connector, transformer and PHY chip. Let's take the simple one port interface. According to many design guidelines , I will have Chassis Gnd plane and Digital Gnd separated underneath a transformer. It means that RJ45 connector pins will be surrounded by chassis GND and will have about 20 mils separation between a pin (hole) and CGND. As well it will be Tx/Rx traces running over the cgnd plane with only 4-5 mil separation. In this type of the design should I expect any Hipot test problems? (actually I already have one, but not 100% sure why) The test is according IEEE 802.3 is 1500V between any lead and Frame/Chassis Gnd. Will 4 mils separation between trace and CGND be enough? or should I remove any chassis gnd underneath the trace (but than how about the impedance?) Any known cases, problems, suggestions, corrections will be highly appreciated. Thanks, Mark Gandler
This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] Archive is being moved, we will announce when it is back on-line. All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc