Alex,

The FCC does not accept Amendment A1:2000 to CISPR 22:1997.  They have
not accepted the ferrite clamps, and with the work that is going on in
CISPR SC I to remove the clamps from CISPR 22:2003 the work in ANSI C63
to add them to ANSI C63.4 has ceased.

Likewise, the FCC does not mandate telecommunication port conducted
emissions testing.

The FCC will allow you to test to the radiated emissions limits from 30
MHz to 1 GHz in CISPR 22 in lieu of the limits called out in 15.109 of
the FCC Rules, but you must still use the test methods in ANSI C63.4.
If testing above 1 GHz is required under the FCC Rules based on the
maximum clock used in the product, that testing must also be performed,
regardless of which limits were used below 1 GHz.

Ghery Pettit
Intel Corporation




From: owner-emc-p...@majordomo.ieee.org
[mailto:owner-emc-p...@majordomo.ieee.org] On Behalf Of Alex McNeil
Sent: Friday, October 10, 2003 1:22 AM
To: emc-p...@majordomo.ieee.org
Subject: CISPR22 applicability for ITE


Hi Guys,

Q1: Is it true that USA and Canada accept CISPR22:1997/A1:2000 instead
of
FCC Part 15 and ICES-003? and only if tested per ANSI C63-4:2002
methods?
Q2: Is it true that Australia now accepts EN55022:1998 or
CISPR22:1997+A1:2000 and/or CISPR22:2003 4th Edition?

Kind Regards
Alex McNeil
Principal Engineer


________________________________________________________________________
This email has been scanned for all known viruses and appropriate
content by the Messagelabs mail service.


This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               emc_p...@symbol.com

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc



This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              emc-p...@hypercom.com
     Dave Heald:               emc_p...@symbol.com

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc

Reply via email to