Sylvia,

On Sun, 20 Mar 2005 11:59:42 -0800 (PST),
  Sylvia Toma <[email protected]> wrote:

> Do you have any information (such as web link, article, etc.)
> you could share with me on the new Denon law?

It is DENAN, the law officially called Electrical Appliance
and Material Safety Law.

> I hate to make this change in our instruction manual
> without knowing for sure that this law is in existence.

If the power cord is a part of a product and the entire
product is legally PS-E marked, the power cord would not
need to be separetely PS-E marked.
In this case, if the power cord is not permanently
connected to the product, some kind of indication (for
example, description in the instruction manual) which
indicates that the power cord is part of the product
would be strongly recommended.

However, I would recommend to use PS-E marked plugs as
far as possible even if it is exempted - the PS-E mark
on the mains plugs indicates that the plug manufacturer
intended to use the plugs in Japan.

Regards,
Tom


Tomonori Sato  <[email protected]>
URL: http://homepage3.nifty.com/tsato/


This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas             [email protected]
     Mike Cantwell            [email protected]

For policy questions, send mail to:

     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to