I am using Schaffner’s Profline Series to perform the above mention immunity test. The NSG 2200-1 (AC Switch) does not provide a low voltage signal where I can connect to the oscilloscope to monitor the percentage dip or voltage variations.
Please advise me on the following: (1) A suitable circuit which I can easily build to step down the voltage such that I can connect directly to the scope (safely). (2) Or any other alternatives? I have an Agilent infiniium digital scope with a 10:1 miniature passive probe 300V max. Thanks. Regards, Wendy Nya Laboratory Manager LabOne Singapore Pte Ltd ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to emc-p...@ieee.org Instructions: http://listserv.ieee.org/listserv/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas emcp...@ptcnh.net Mike Cantwell mcantw...@ieee.org For policy questions, send mail to: Richard Nute: ri...@ieee.org Jim Bacher: j.bac...@ieee.org All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc