In message <003f01c68d83$8e612080$6de107c3@x8i2i2>, dated Sun, 11 Jun 
2006, Jeff Chambers <[email protected]> writes

>Now, we have here a Seaward 'Screened Room', about ten years old, 
> which is basically a 'tent' of metallised fabric draped over a metal 
>framework, with a metal floor. It was sold for emc work, has a 
>solid-looking door, plus a filtered mains inlet.

Is the filter still OK? The capacitors might be open-circuit.

>Its about 5m x 3m x 3m, and I'd like to use it to provide confidence 
>that designs are well within emissions limits, rather than try to 
>justify things close to a limit. Its literature of the time claimed 
>60dB to 80dB attenuation.
> 
>But... it doesn't seem to offer much attenuation to FM radio signals!

Think 'tarnishing'.  All joints probably need cleaning **carefully**. 
Ask Seaward how to do it.
> 
>It's only ground is via the mains inlet, i.e. not much of an rf ground. 
>Otherwise it's just sat on the factory floor. I have a building girder 
>very close by emerging from the floor - should I ground the room to 
>that?

Just try it! But I doubt that earthing is the problem.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
2006 is YMMVI- Your mileage may vary immensely.

John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to