>Comparing the emissions limits at 3 meter (lets say 40dbuV/m) verses 
>the field strength of 3V/m (immunity test), if my math is correct, 
>isn't 3V/m about 130dbuV/m (e-field)?

Yes.
>At 10cm (4 inches), isn't the maximun field strength of a Class B 
>product about 70dbuV/m?

No, you can't rely on the inverse square law in the near field.


-- 