The UFA is as per the standard, 1.5x1.5m, 0.8m above GRP

Sent from Wendy.Nya iPhone

On Sep 27, 2011, at 9:44 PM, "Charlie Blackham" <emcp...@sulisconsultants.com>
wrote:

> Wendy
> 
> What size UFA (uniform field area) are you trying to create?
> What size are your EUT (i.e. what sixe UFA do you need?)
> 
> Regards
> Charlie
> 
> -----Original Message-----
> From: WNya [mailto:wendy...@yahoo.com] 
> Sent: 27 September 2011 14:28
> To: EMC-PSTC@LISTSERV.IEEE.ORG
> Subject: [PSES] Still on Radiated Immunity
> 
> Dear EMC Experts,
> 
> I have a 4x3m chamber. I encounter much difficulty to calibrate the chamber
> every year. I am using a Schwarzbeck 9128DS and a AR systems. 
> 
> Does anyone know any 'tricks' to 'tweak' the chamber to perfection?
> 
> PS: PAMP is 250W, up to 1GHz.
> 
> Sent from Wendy.Nya iPhone
> 
> -
> ----------------------------------------------------------------
> This message is from the IEEE Product Safety Engineering Society emc-pstc
> discussion list. To post a message to the list, send your e-mail to
> <emc-p...@ieee.org>
> 
> All emc-pstc postings are archived and searchable on the web at:
> http://product-compliance.oc.ieee.org/
> Graphics (in well-used formats), large files, etc. can be posted to that
> URL.
> 
> Website:  http://www.ieee-pses.org/
> Instructions:  http://listserv.ieee.org/request/user-guide.html
> List rules: http://www.ieee-pses.org/listrules.html
> 
> For help, send mail to the list administrators:
> Scott Douglas <emcp...@radiusnorth.net>
> Mike Cantwell <mcantw...@ieee.org>
> 
> For policy questions, send mail to:
> Jim Bacher:  <j.bac...@ieee.org>
> David Heald: <dhe...@gmail.com>
> 
> -
> ----------------------------------------------------------------
> This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<emc-p...@ieee.org>
> 
> All emc-pstc postings are archived and searchable on the web at:
> http://product-compliance.oc.ieee.org/
> Graphics (in well-used formats), large files, etc. can be posted to that URL.
> 
> Website:  http://www.ieee-pses.org/
> Instructions:  http://listserv.ieee.org/request/user-guide.html
> List rules: http://www.ieee-pses.org/listrules.html
> 
> For help, send mail to the list administrators:
> Scott Douglas <emcp...@radiusnorth.net>
> Mike Cantwell <mcantw...@ieee.org>
> 
> For policy questions, send mail to:
> Jim Bacher:  <j.bac...@ieee.org>
> David Heald: <dhe...@gmail.com>

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at:
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <emcp...@radiusnorth.net>
Mike Cantwell <mcantw...@ieee.org>

For policy questions, send mail to:
Jim Bacher:  <j.bac...@ieee.org>
David Heald: <dhe...@gmail.com>

Reply via email to