I have had a fair amount of experience in making sure that military systems
can meet the MIL-STD-461 RS103 requirement of 200 V/M. However, we are now
seeing system requirements for levels from MIL-STD-464 (and other places).
These new requirements invoke immunity to levels such as 8 GHz to 10 GHz at
21,000 V/M (peak pulse).
 
I would like to get an idea of the amount of risk involved in going to that
next level. Has anyone had any experiences with meeting the 461 200 V/M and
then trying for the 464 levels? Does equipment that meets 461 usually meet
those 464 levels? If not, what kind of failures do you see (cable arcing,
internal component destruction)?
 
Thanks in advance!
 
Ed Price
ed.pr...@cubic.com <mailto:ed.pr...@cubic.com>      WB6WSN
NARTE Certified EMC Engineer & Technician
Electromagnetic Compatibility Lab
Cubic Defense Applications
San Diego, CA  USA
858-505-2780 (Voice)
858-505-1583 (FAX)
Military & Avionics EMC Is Our Specialty