In message <009d01c970cb$a4087720$ec196560$@dk>, dated Wed, 7 Jan 2009, 
Niels Hougaard <n...@bolls.dk> writes:

>I am looking for the field strength that implantable pacemakers are 
>designed to work perfect at. Frequency range in question is 10 - 50 kHz.

This is a very complex issue, still under study in CENELEC TC106X. 
Someone at Danish Standards may well be able to give you the up-to-date 
situation.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
Things can always get better. But that's not the only option.