PSNet,

 

                There was a lot of work in the US to harmonize IEC 60204
with NFPA 79 about a decade ago.  

 

                Machine manufacturers are using NFPA 79 as a proxy for 60204
since their shops and suppliers understand the requirements expressed in
this way.  

 

                More power to them; I'd like to see US made machines bear a
NFPA 79 field inspection sticker when shipped overseas to reinforce this
idea.   

 

                One set of requirements worldwide! - Here's a bumper sticker
for machines.  

 

:>)     br,     Pete

 

Peter E Perkins, PE

Principal Product Safety Engineer

PO Box 23427

Tigard, ORe  97281-3427

 

503/452-1201     fone/fax

p.perk...@ieee.org

 


-
----------------------------------------------------------------