Hello,
i just started using EMC2 and things are looking well.
I added some X and Y linit switches to the parallel port 0, pin 10 and 11. The 
problem is that they are active low switches (gnd when pressed, 5V when open). 
I can't seem to make EMC2 recognise this.
 
I tried this:
 
newsig Xlimits bit
setp parport.0.pin-10-invert TRUE
linkps parport.0.pin-10-in => Xlimits
linksp Xlimits => axis.0.neg-lim-sw-in
linksp Xlimits => axis.0.pos-lim-sw-in
 
However, I get a "parameter or pin setp parport.0.pin-10-invert"  not found 
error.
 
What can I do ?
 
Regards,
 
Ronald Wijngaarde

-------------------------------------------------------------------------