On Tue, Dec 16, 2008 at 03:58:46PM -0500, Matt Shaver wrote:
> I have a lathe that has an automated tool turret, which I had working
> with a version of TRUNK several months ago. I cvs updated my copy of
> TRUNK and recompiled yesterday and I now have a problem in
> Classicladder. I have one S32 input to Classicladder which is connected
> to the tool prep number from iocontrol. The tool prep number changes
> when a "Tn" block is executed (in MDI), and shows up correctly in the
> HAL configuration display in Axis, both on iocontrol.0.tool-prep-number,
> and on classicladder.0.s32in-00.
>
> The problem is that the value of %W0 in Classicladder stays equal to 0,
> not the value of classicladder.0.s32in-00.
Date: 2008/11/23 01:44:00
Author: cmorley
Branch: HEAD
Tag: (none)
Log:
Created new variables IW and QW to represent S32 in and out pins
instead of mapping them to W variables. Defaults to ten of each.
Aligns us with mainsteam Classicladder. ladder programs will need to
be updated, HAL files will be fine
------------------------------------------------------------------------------