On Sun, Dec 26, 2010 at 3:41 PM, Stuart Stevenson <stus...@gmail.com> wrote:

> ok - thanks for the nudge - I will explore further
>
> --
> dos centavos
>

uh - further exploration revealed a diagnostician error. When checking
joint_2 drive you really need to swap joint_2 with joint_1 instead of
joint_0 with joint_1. Hal config showed no glaring problems but realizing
the count starts at the bottom right instead of the bottom left caused me to
recognize I was swapping a good drive on a working axis with a good drive on
a working axis and then checking the non-working axis again (and again - and
again - ad nauseum).
a smoked fuse in the non-working drive should be a simple fix.
I should be able to scrape a little egg off my face and have on omelet for
supper. :)
having some fun now
thanks
Stuart
-- 
dos centavos
------------------------------------------------------------------------------