On 29 December 2010 20:46, Igor Chudov <[email protected]> wrote: > Andy, this is very interesting. How do I configure this gearchange, so that > when a microswitch is turned on, it uses Gear 1, and when microswitch is > off, it uses gear 0?
That rather depends on how your existing system is set up. It would be wired between the motion.spindle-speed pins, and the inputs to the PWM generator (or however spindle speed is controlled) and the gearchange.0.sel pin would be wired to the microswitch. You might need to wire the NC contacts, as that version of gearchange is rather prescriptive as far as which is the higher gear is concerned. -- atp "Torque wrenches are for the obedience of fools and the guidance of wise men" ------------------------------------------------------------------------------ Learn how Oracle Real Application Clusters (RAC) One Node allows customers to consolidate database storage, standardize their database environment, and, should the need arise, upgrade to a full multi-node Oracle RAC database without downtime or disruption http://p.sf.net/sfu/oracle-sfdevnl _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users