On Wed, Dec 29, 2010 at 3:02 PM, andy pugh <[email protected]> wrote:
> On 29 December 2010 20:46, Igor Chudov <[email protected]> wrote: > > Andy, this is very interesting. How do I configure this gearchange, so > that > > when a microswitch is turned on, it uses Gear 1, and when microswitch is > > off, it uses gear 0? > > That rather depends on how your existing system is set up. It would be > wired between the motion.spindle-speed pins, Andy, sorry, what do you mean? and the inputs to the PWM > generator (or however spindle speed is controlled) Right now I do not control my spindle speed from EMC at all. I do it by buttons that are electrical in nature, but are actuated by hand. The mill has a variable speed drive and I change speed by pressing buttons that run an air motor. > and the > gearchange.0.sel pin would be wired to the microswitch. You might need > to wire the NC contacts, as that version of gearchange is rather > prescriptive as far as which is the higher gear is concerned. > > OK, that's not a problem to use NC contacts. Does this mean that I do not need to even define gearchange.1.sel pin at all if I set gearchange.0.sel to be connected to the microswitch? Do you have gearchange implemented anywhere? Thanks Andy, this gearchange seems to be a godsend, and a good self documenting feature that is easies than a bunch of muxes to understand. i ------------------------------------------------------------------------------ Learn how Oracle Real Application Clusters (RAC) One Node allows customers to consolidate database storage, standardize their database environment, and, should the need arise, upgrade to a full multi-node Oracle RAC database without downtime or disruption http://p.sf.net/sfu/oracle-sfdevnl _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users