Thanks.

I had the right HOME_SEQUENCE value of -1 but wasn't aware of that it was
necessary to manually home the axis after a home-all.

Now can try making a button for homing the A-axis instead of traveling
menus :-)

/Niels

> On 18 July 2011 23:48, Niels Jalling <ni...@jalling.dk> wrote:
>
>> How do I home the A-axis ? Or which parameter needs to be changed in
>> inifiles?
>
> Delete the HOME_SEQUENCE line from the A-axis definition in the INI
> file. Or, alternatively, and possibly a bit clearer, set it to -1.
>
>
> --
> atp
> "Torque wrenches are for the obedience of fools and the guidance of wise
> men"
>


------------------------------------------------------------------------------