Hello all;

New touch probe (from cnc4pc) attached to an input on my Gecko G540. LinuxCNC 
2.5.0, upgraded last weekend.


I got a routine from the www.linuxcnc.org web site (topic 18421, dated 4 months 
ago) with "center_material.ngc"

Working through it, it does Z, X, but fails on the Y axis.

error "Probe is already clear when starting a G38.4 or G38.5 move".

Munging that ngc file; changing the parameters to readable names, and I work in 
metric;

G91
G38.2 F#<FASTPROBE> Y#<Y_SIZE> (probe end of Y)
 O181 IF [#5070 lt 1]
 (MSG, Probe not complete Y missed)
 G90
 M2
 O181 ENDIF

M1

;;slow probe here
(debug, A)

G38.4 F#<FASTPROBE> Y-.50 (back probe off target)
 O182 IF [#5070 lt 1]
 (MSG, Probe not complete Y did not clear retract)
 G90
 M2
 O182 ENDIF

The G38.2 works; the G38.4 fails.

q1) Why fail on the Y axis, when the same routines work on X and Z axes?

q2) This was a known bug, but fixed a while ago. Or did it not get fixed for Y 
axis??

q3) This routine is on the linuxcnc web site; why am I having problems, or do 
others???

thank you;


-----------------------------------------------------------
John A. Stewart
[email protected]

------------------------------------------------------------------------------