Marius Liebenberg wrote:
> I am finalizing my enclosure for my small mill conversion and need to 
> ask about coolant flow rate. I can get a 1/4 HP coolant pump with a flow 
> rate of 74L/min. Is this good enough for aluminium milling?
> I have a holding capacity of 160L of coolant, will this be sufficient?
>
>   
I suspect I have 1 - 2 L/min with my tiny pump, and it can cause a flood.
74 L/Min is crazy unless you have a 20 Hp spindle.  160 L?  I have about
3 gallons, so that is 12 L.  You say "small mill", the coolant system I
mention above is on a Bridgeport mill with a 1 Hp spindle motor.  If it
is fully enclosed, then the splashing is less a concern, but you still
can't use more than a few L/min or it will blow your coolant nozzle
apart.  I use the 1/4" Loc-Line series, and just one small nozzle.
A Litre of water per minute can remove a LOT of heat.

Jon

------------------------------------------------------------------------------