and Andy has the better solution...

(fixing the button problem and the problem you didn't even know you 
had.. :) )

sam
On 2/28/2014 9:39 AM, andy pugh wrote:
> On 28 February 2014 15:18, Mark Tucker <m...@rmtucker.f2s.com> wrote:
>
> I have the following in my hal file:-
>> # This output is on DB25-14 and is currently tied to spindle control
>> (M3/M5)
>> net Output1 bb_gpio.p8.out-13 => halui.spindle.is-on
>>
> That's sort-of the wrong pin (it is a userspace tell-tale about spindle
> state, not the intended command pin).
> use motion.spindle.is-on instead. (and associated pins)