On 12/20/2015 05:06 PM, John Thornton wrote:
> Well it works fine till I plug in the VFD so I guess I'll have to rewire
> the machine and my shop again :(
>
>
Well, that is now very important information!  Just plugging 
in the VFD, without having it start the spindle motor causes 
the problem? Then you are probably right.  If you only had 
problems when the spindle was running, then the line 
reactors might help.

I put a commercial line filter box on the VFD on my mill, I 
was having interference in a couple units, but only when the 
VFD was running the spindle.  The filter fixed it.

Jon

------------------------------------------------------------------------------
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users