John,

Thanks for the direction, I'll look at that for the limits.  My machine is
the _one_ switch type for limits on both ends without a home.  I didn't
setup a home, but after using the mill for the last year, probably a good
idea.

I have been running 2.6.11 on a different harddrive, so good when I need to
go.

I do think I'll buy that O-scope, only because I've always wanted one and
it seems like that one is a decent enough hobby scope for someone like me...

Regards,
Mark

Mark,

The short answer is replacing the limit/home switch wiring with shielded
cable and grounding it to one place was the difference in making the
sserial errors go away. Unless you need 2.7 back up to 2.6 till you get
rid of the sserial errors.

JT
------------------------------------------------------------------------------