On 21 April 2017 at 12:43, Valerio Bellizzomi <vale...@selnet.org> wrote:

> the current parameters are, step on-time 3000, step space 3000, dir hold
> 5000, dir setup 5000
>
> ok, that's a little step forward :-)

It is rarely necessary to make the step and space lengths as short as
possible, you tend to run into physical limits first.
Try 5000 for step-length and step-space.

You can also try inverting the step pulse polarity.

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1916

------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users