On 05/25/2020 02:50 PM, N wrote:
Do anyone here have any suggestion for FERROR and MIN_FERROR values?



It depends on your "user units", as well as the general accuracy and speed of the machine. FERROR is a multiplier to velocity in user units/second that is added to MIN_FERROR. MIN_FERROR is the allowable following error with the machine not moving.

On a servo system, you should have Halscope graph the following error and find out what your actual errors are, and then set MIN_FERROR accordingly. Then, set FERROR to
accommodate larger error at rapid traverse speed.

There's no one good value for everybody.

Jon


_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to