If you have some transformers lying around you could stack the secondaries to get 440V They don't need to be step-up, just sum the secondaries. You need to have them all in phase obviously.
Then use a small, single phase 440V VFD Most VFD's under 1Hp accept single or 3ph, but I don't know about 440V. Maybe 380V I don't know if you can use a 110V:24V transformer in reverse, or whether you'll cook it. Worth a try... Roland On Tue, 15 Jun 2021 at 00:36, Gregg Eshelman via Emc-users < [email protected]> wrote: > The motor is in a Hardinge UM mill, less than 1 horsepower. It cannot be > switched to 220V. Any way to get it running off 220 volts, three or single > phase, without breaking a few banks? > > _______________________________________________ > Emc-users mailing list > [email protected] > https://lists.sourceforge.net/lists/listinfo/emc-users > _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users