On the dura, is the issue that it just moves the decimal instead of
converting the values? That's just a parameter change.

I don't recall the dura using tc controls, i thought those started with td?
I may be wrong, it's been a while since i saw one of those in the wild.

Phil T.
The Feral Engineer

Check out my LinuxCNC tutorials, machine builds and other antics at
www.youtube.com/c/theferalengineer

Help support my channel efforts and coffee addiction:
www.patreon.com/theferalengineer

On Fri, Jul 16, 2021, 2:21 PM Ralph Stirling <ralph.stirl...@wallawalla.edu>
wrote:

> I forbid G20 on the Mori Duraturn in my lab for that exact reason.  It has
> a Fanuc 0i-TC.  I figure 21st century engineering students should develop
> some feel for metric measurements anyway.  Just to be safe I also require
> G21 on our Mori NVX mill even though it uses a Mits control that handles it
> better.
>
> -- Ralph
>
> On Jul 16, 2021 9:11 AM, Todd Zuercher <to...@pgrahamdunn.com> wrote:
> CAUTION: This email originated from outside the Walla Walla University
> email system.
>
>
> I need to voice some frustration.  So pardon the OT post
>
> Fanuc is making me pull my hair out.  You'd think a cnc control built
> within the last 20 years could handle switching between G20 and G21 modes!
> It's a flippin command line code that can be issued in a file for goodness
> sakes!
>
> We bought a used machine that was being used in G21 mode.  And I've been
> banging my head on this thing for a week.  Can't figure out why all of the
> work coordinates are so screwed up, reset them and then they are messed up
> again, G91G28 commands won't work and keep over traveling (but G90G53 does)
> and the home positions keep moving around.  Turns out its all because a
> stupid Fanuc 180iM control built in 2003 can't handle switching between G21
> and G20 modes without 3 power cycles, a couple of parameter changes and
> completely resetting all the work coordinate systems settings.  FOR
> REAL!!!!!!!!!!!!!!  Even Mach3 can do this right! If this is the case why
> even have G20/G21 available as a G-code! It should only be a parameter
> setting that can't be changed from a file.  This is even more annoying than
> G92 or jogging a paused program, at least a power cycle can fix those screw
> ups.
>
> Todd Zuercher
> P. Graham Dunn Inc.<
> https://nam12.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.pgrahamdunn.com%2Findex.php&amp;data=04%7C01%7Cralph.stirling%40wallawalla.edu%7Cfbcd3391855548c9fb0808d948744cc8%7Cd958f048e43142779c8debfb75e7aa64%7C0%7C1%7C637620486609683146%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000&amp;sdata=6aFWrgW7S5RrjTYlDRZtghl1oQRnLHYJnxE4K1tFpkc%3D&amp;reserved=0
> >
> 630 Henry Street
> Dalton, Ohio 44618
> Phone:  (330)828-2105ext. 2031
>
>
> _______________________________________________
> Emc-users mailing list
> Emc-users@lists.sourceforge.net
>
> https://nam12.safelinks.protection.outlook.com/?url=https%3A%2F%2Flists.sourceforge.net%2Flists%2Flistinfo%2Femc-users&amp;data=04%7C01%7Cralph.stirling%40wallawalla.edu%7Cfbcd3391855548c9fb0808d948744cc8%7Cd958f048e43142779c8debfb75e7aa64%7C0%7C1%7C637620486609683146%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000&amp;sdata=aMuCUwk%2FQ3zgr2I6DnJCpqL3DusQeoX9D%2FI2aJPvAwI%3D&amp;reserved=0
>
> _______________________________________________
> Emc-users mailing list
> Emc-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/emc-users
>

_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to