On Fri, 8 Sept 2023 at 17:07, gene heskett <ghesk...@shentel.net> wrote:

> Now I've another data missmatch, since when is a "not" not a true/false
> invertor? I can't feed it into a mux2 in for the sample to hold???

What is the datatype of your mux2?

Works for me:

andypugh@rm-one:~/linuxcnc-dev$ halrun
halcmd: loadrt not count=1
Note: Using POSIX realtime
halcmd: loadrt mux_generic config=bb2
halcmd: net test not.0.out mux-gen.00.in-bit-01
halcmd: show sig
Signals:
Type          Value  Name     (linked to)
bit           FALSE  test
                         ==> mux-gen.00.in-bit-01
                         <== not.0.out

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1912


_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to