Hi,
Regarding the EngineID, i can't find any command to manage this parameter and
nothing relevant to this in the KB.
Is it possible for you to reset the configuration through factory default
option of the boot menu ? Then upload the original configuration without snmp
EngineID parameter if it is shown in snmp section ?
If it's doesn't work contact GTAC.
Regarding MSTP config name, as described in the knowledgebase, TB "10679 :
Unstable SecureStack through f/w x.01.05.0004 with set spantree mstcfgid
cfgname Automatically Added to the Config" :
- If you are in MSTP mode :
set spantree mstcfgid cfgname default (Or any other words identical for
all your switch in a STP domain as already suggested by Jason)
- If you are in RSTP mode :
'clear spantree mstcfgid'
Bye,
Sylvain
-----Message d'origine-----
De : Parker, Jason [mailto:[email protected]]
Envoyé : mercredi 12 mai 2010 03:47
À : Enterasys Customer Mailing List
Objet : RE: [enterasys] Duplicate EngineID
All,
The MAC address in this command spantree mstcfgid cfgname '00-11-88-97-89-58'is
the next unit in the stack that will become manager I always change this
command to spantree mstcfgid cfgname 'guest'
Please try this and then check the engine ID
Thank you
Jason
-----Original Message-----
From: Nick Allen [mailto:[email protected]]
Sent: Tuesday, May 11, 2010 8:25 PM
To: Enterasys Customer Mailing List
Subject: RE: [enterasys] Duplicate EngineID
Thanks Zoltan,
No the MAC addresses are different, but engineIDs are the same.
WhitSt C2 1st Floor(su)->show snmp engineid
EngineId: 80:00:15:f8:03:00:11:88:97:89:58:00
Engine Boots = 24
Engine Time = 642
Max Msg Size = 2048
WhitSt C2 1st Floor(su)->
TEQLON-sw02(su)->show snmp engineid
EngineId: 80:00:15:f8:03:00:11:88:97:89:58:00
Engine Boots = 4
Engine Time = 28684
Max Msg Size = 2048
TEQLON-sw02(su)->
What did look somewhat relevant though was that I found a rogue line of config
on the "WhitSt C2 1st Floor" switch:
spantree mstcfgid cfgname '00-11-88-97-89-58'
Not sure who put that in there or why but that name seems to relate to the mac
address of the other switch and I was hoping the engineID might be based on
that.
I removed that line and rebooted that switch, but it's made no difference.
Any last ideas before I open a support call? It's not urgent.
Thanks,
N.
This e-mail is intended only for the named person or entity to which it is
addressed and contains valuable business information that is proprietary,
privileged, confidential and/or otherwise protected from disclosure. If you
received this e-mail in error, any review, use, dissemination, distribution or
copying of this e-mail is strictly prohibited. Please notify us immediately of
the error via e-mail to [email protected] and please delete the
e-mail from your system, retaining no copies in any media. We appreciate your
cooperation.
-----Original Message-----
From: Zoltan Ori [mailto:[email protected]]
Sent: Tue 5/11/2010 9:22 PM
To: Enterasys Customer Mailing List
Subject: Re: [enterasys] Duplicate EngineID
AFAIK the engine ID is partly formed from the MAC address of the switch. Do the
switches have the same MAC address?
Zoltan
On Tuesday 11 May 2010 12:09, you wrote:
> Hi,
>
> I seem to have two C-series switches with duplicate engineID's - is
> there a way to get a switch to generate a new one?
>
> N.
---
To unsubscribe from enterasys, send email to [email protected] with the body:
unsubscribe enterasys [email protected]
---
To unsubscribe from enterasys, send email to [email protected] with the body:
unsubscribe enterasys [email protected]
---
To unsubscribe from enterasys, send email to [email protected] with the body:
unsubscribe enterasys [email protected]