Nick ! Did you look at Show port lacp port <phy_port> status detail ? There you can see admin & oper state.
Did you try Set port lacp port <phy_port> enable/disable ? Volker Kull BELL Computer-Netzwerke GmbH Ohmstr. 6 - 76229 Karlsruhe (Germany) Tel: +49 721/6624993-0 Fax: +49 721/6624993-30 Email: [email protected] ________________________________ Von: Nick Allen An: Enterasys Customer Mailing List Gesendet: Thu Dec 23 20:28:06 2010 Betreff: Re: [enterasys] HP NIC Teaming... Hi Jay, Sorry - yes typo: set vlan egress 100 ge.3.35;ge.3.45;lag.0.2 untagged Cheers, N. On 23 December 2010 18:48, Auger, Jay (IS) <[email protected]> wrote: Just want to make sure, in your lacp commands you reference ports ge.3.35 & ge.3.45 but in your VLAN egress statement you reference ge.3.36 & ge.3.46. Hopefully, this is just a typo. Jay ________________________________________ From: Nick Allen [[email protected]] Sent: Thursday, December 23, 2010 1:33 PM To: Enterasys Customer Mailing List Subject: [enterasys] HP NIC Teaming... Hi guys, Hopefully a very basic question for someone. With HP NIC Teaming on Windows 2008 R2, we've been advised that "Switch assisted load balancing with fault tolerance (SLB)" is the best option for a NIC team connected to an Enterasys C2G stack, provided we manually create the LAG. I've created the LAG as follows: set lacp aadminkey lag.0.2 102 set port lacp port ge.3.35 aadminkey 102 set port lacp port ge.3.45 aadminkey 102 I've done quite a few switch-to-switch LAG's so am familiar with seeing entries under "Attached ports" when the LAG is active but this one shows none: ================================================ C2Stack(su)->show lacp lag.0.2 Global Link Aggregation state: enabled Single Port LAGs: disabled Aggregator: lag.0.2 Actor Partner System Identifier: 00:11:88:64:7F:AA 18:A9:05:60:FA:10 System Priority: 32768 32768 Admin Key: 102 Oper Key: 102 768 Attached Ports: None. C2Stack(su)-> ================================================ The partner Mac address is the Mac address of the Team, but the question is - should I be seeing ge.3.35 and ge.3.45 as "Attached Ports:" if it's functioning correctly? These ports are in VLAN 100 by the way, so I've also made sure the same VLAN can egress the lag: set vlan egress 100 ge.1.36-46;lag.0.2 untagged Thanks, Nick. -- This e-mail is intended only for the named person or entity to which it is addressed and contains valuable business information that is proprietary, privileged, confidential and/or otherwise protected from disclosure. If you received this e-mail in error, any review, use, dissemination, distribution or copying of this e-mail is strictly prohibited. Please notify us immediately of the error via e-mail to [email protected] and please delete the e-mail from your system, retaining no copies in any media. We appreciate your cooperation. * --To unsubscribe from enterasys, send email to [email protected]<mailto:[email protected]> with the body: unsubscribe enterasys [email protected] --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected] -- Nick Allen IT Director TBWA\UK GROUP 76-80 Whitfield Street London, W1T 4EZ Direct: +44 20 7573 6792 Mobile: +44 7970 121 609 Main: +44 20 7573 6500 Reg. Office: TBWA UK GROUP Ltd, 239 Old Marylebone Road, London, NW1 5QT Company Reg. #: 4332188 (UK) Company VAT #: GB 656 8994 61 -- This e-mail is intended only for the named person or entity to which it is addressed and contains valuable business information that is proprietary, privileged, confidential and/or otherwise protected from disclosure. If you received this e-mail in error, any review, use, dissemination, distribution or copying of this e-mail is strictly prohibited. Please notify us immediately of the error via e-mail to [email protected] and please delete the e-mail from your system, retaining no copies in any media. We appreciate your cooperation. * --To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]
smime.p7s
Description: S/MIME cryptographic signature