Hi, Question 1: There is no way to avoid downtime if switch manager was moved!!
Question 2: if you do a "save config" all switches will get the same config. To check that - "show switch status" The problem was the automatic config save - a stand-alone switch save every 2 minutes the config / a stack only save every 30 minutes the config. I guess you have move management before switch config has automatically saved. If you do that manually (save config) you will be right! Regards -----Ursprüngliche Nachricht----- Von: [email protected] [mailto:[email protected]] Gesendet: Samstag, 16. Juli 2011 15:08 An: Enterasys Customer Mailing List Betreff: [enterasys] Move Management in a Stack Hi all, 1) Does someone know a way to move the management from one switch to another without having downtimes? It seems that "set switch movemanagement" command will result in a downtime (1min or more) of all switches member of the stack(C5 or B5 stacks). 2) How to ensure that all Switches (C5) of the stack have the same config? I noticed that stacking a switch with a configured host IP-Address (mgmt) was not overwritten by the configuration of the "Master" switch. Once this second switch was designated as "Master" (due to powercycle of the first switch) the Host IP-Address was again in the config. Regards, Franco --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]