I have replaced PSU's and then the replacements work fine. I have been leaning 
towards a PSU issue, but a chassis or MB issue is a possibility.

Patrick Printz
Network Infrastructure

Quinsigamond Community College
670 West Boylston Street
Worcester, MA 01606-2092
w. 508-854-7517
c. 508-726-9529


"If a man is called a street sweeper, he should sweep streets even as 
Michelangelo painted, or Beethoven composed music, or Shakespeare wrote poetry. 
 He should sweep streets so well that all the hosts of heaven and Earth will 
pause to say, Here lived a great street sweeper who did his job well."
~Martin Luther King, Jr.

From: Doyle, Tim [mailto:[email protected]]
Sent: Thursday, February 09, 2012 10:39 AM
To: Enterasys Customer Mailing List
Subject: RE:[enterasys] G3-PWR-POE: PoE-Power-Supply failure

Same for us also.  I actually replaced one of the power supplies 2 times and 
the 3rd one did the same thing.  I haven't gotten around to the RMA yet since I 
think the only logical step would be to replace the whole G3 switch to see if 
maybe the chassis or motherboard is causing the issue.

Tim

From: Volker Kull [mailto:[email protected]]<mailto:[mailto:[email protected]]>
Sent: Thursday, February 09, 2012 2:57 AM
To: Enterasys Customer Mailing List
Subject: [enterasys] G3-PWR-POE: PoE-Power-Supply failure

Hello all,

We have a rising number of failures with G3-PWR-POE. After a period of 10 to 18 
month after power up, these PoE-PS go into failure on secondary side (DC). On 
different worldwide sites we using G3 with dual PoE-PS connected to UPS and 
normal power circuit and populated with not more than two 24-port modules with 
PoE. The real PoE consumption is not really high in relation to the max power 
of two PWRs.  In other installations with G3 and G3-PWR without PoE we have 
much less problems. These problems occur on different sites and on different 
power sources (UPS or normal power).

Does someone has the same problems ?

viele Grüße

Volker Kull
Geschäftsstellenleiter Süd

BELL Computer-Netzwerke GmbH
Ohmstr. 6 - 76229 Karlsruhe - Germany
Tel:     +49 (0) 721 6624993-0
Fax:    +49 (0) 721 6624993-30
e-mail   [email protected]<blocked::mailto:[email protected]>
web      www.bell.de<blocked::http://www.bell.de/>

[Beschreibung: BELL]

Geschaeftsfuehrer: Dipl. Ing. Tobias Groene
Sitz der Gesellschaft: Bonn, HRB 6444 Amtsgericht Bonn
*******************************************************************************************************************
Diese E-Mail kann vertrauliche Informationen enthalten. Wenn Sie nicht der 
richtige Adressat sind,
informieren Sie bitte sofort den Absender und vernichten Sie diese Mail. Das 
unerlaubte Kopieren
sowie die unbefugte Weitergabe dieser Mail ist nicht gestattet.
This e-mail may contain confidential information. If you are not the intended 
recipient please notify
the sender immediately and destroy this e-mail. Any unauthorised copying, 
disclosure or distribution
of this e-mail`s content is strictly forbidden.
*****************************************************************************************************************



  *   --To unsubscribe from enterasys, send email to 
[email protected]<mailto:[email protected]> with the body: unsubscribe enterasys 
[email protected]<mailto:[email protected]>

---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

<<inline: image001.png>>

Reply via email to