Make sure your console cable is plugged into the switch that is manager for the 
stack.  Check the management led on the front of each switch.  The one that is 
green is the manager for the stack.

From: Fernando Pruneda [mailto:[email protected]]
Sent: Wednesday, December 05, 2012 9:46 AM
To: Enterasys Customer Mailing List
Subject: Re: [enterasys] Clear config

you essentially wiped the running config.

do you have a backup of the config that you can restore it to?


On Wed, Dec 5, 2012 at 9:44 AM, Baack, Adam 
<[email protected]<mailto:[email protected]>> wrote:
New customer here so excuse my ignorance. I just did a clear config all on a B5 
stack and it booted up to a prompt that say (switch 1) and no commands work. 
What did I do?

Thanks.

Adam Baack
Sent from my iPhone


***IMPORTANT MESSAGE***
This message is intended for the use of the person or entity to
whom it is addressed and may contain information that is privileged
and confidential, the disclosure of which is governed by applicable
law. If the reader of this email is not the intended recipient or
the employee or agent responsible to deliver it to the intended
recipient, you are hereby notified that any dissemination,
distribution or copying of this information is STRICTLY PROHIBITED.
If you have received this email by error, please notify us
immediately and destroy the related message. This footnote also
confirms that this email message has been swept for the presence of
computer viruses, worms, hostile scripts and other email-borne
network threats. PLEASE NOTE: Florida has a very broad public
records law. Most written communications to or from government
officials are public records available to the public and media upon
request. Your email communications may be subject to public
disclosure per Sec. 119 F.S.

---
To unsubscribe from enterasys, send email to 
[email protected]<mailto:[email protected]> with the body: unsubscribe enterasys 
[email protected]<mailto:[email protected]>


  *   --To unsubscribe from enterasys, send email to 
[email protected]<mailto:[email protected]> with the body: unsubscribe enterasys 
[email protected]<mailto:[email protected]>

---
To unsubscribe from enterasys, send email to [email protected] with the body: 
unsubscribe enterasys [email protected]

Reply via email to