Personally, given how cheap these are, and how bad a possible problem could
end up (burning your house down), I'd just replace the affected cells.   I
know that's probably not what you want to hear, but  people have had fires
messing with these cells!

On Tue, Jun 3, 2025 at 10:01 PM John Lussmyer via EV <[email protected]>
wrote:

> On 6/3/2025 9:10 PM, Mr. Sharkey via EV wrote:
> > Two of the modules in my 2P5S Leaf battery conversion for an Electrak
> > E20 tractor seem to have failed in an identical manner. The two
> > modules are a paralleled pair, with the voltage sense terminals bussed
> > together.
>
>
> Umm, WHY connect the sense terminals together?  As far as I can tell, it
> just provides another possible fault.
> I left mine separated in the trucks old pack (3px40s) and only connected
> BMS sense wires to those.
>
> _______________________________________________
> Address messages to [email protected]
> No other addresses in TO and CC fields
> HELP: http://www.evdl.org/help/
>
>