Ok, so I installed the rpm, and lo and behold, my mobo is finally supported.
Running sensors-detect, I was able to find several items of use, and I added them to modules.conf, as I was told by the script. I have loaded: w83781d eeprom i2c-proc i2c-dev i2c-philips-par parport i2c-elv i2c-algo-bit i2c-nforce2 i2c-core And now I am running sensors at the command prompt: # sensors eeprom-i2c-0-50 Adapter: SMBus nForce2 adapter at 5000 Algorithm: Non-I2C SMBus adapter eeprom-i2c-0-51 Adapter: SMBus nForce2 adapter at 5000 Algorithm: Non-I2C SMBus adapter as99127f-i2c-1-2d Adapter: SMBus nForce2 adapter at 5500 Algorithm: Non-I2C SMBus adapter VCore 1: +1.64 V (min = +1.47 V, max = +1.61 V) ALARM VCore 2: +1.66 V (min = +1.47 V, max = +1.61 V) +3.3V: +3.32 V (min = +3.13 V, max = +3.45 V) +5V: +4.99 V (min = +4.72 V, max = +5.24 V) +12V: +11.86 V (min = +10.79 V, max = +13.19 V) -12V: -12.40 V (min = -0.00 V, max = -0.00 V) -5V: -4.70 V (min = -0.00 V, max = -0.00 V) fan1: 14361 RPM (min = 3000 RPM, div = 2) fan2: 3139 RPM (min = 3000 RPM, div = 2) ALARM fan3: 5192 RPM (min = 3000 RPM, div = 2) temp1: +33°C (limit = +60°C) temp2: +35.4°C (limit = +120°C, hysteresis = +100°C) temp3: +255.4°C (limit = +120°C, hysteresis = +100°C) vid: +1.550 V alarms: beep_enable: Sound alarm enabled Now, what do I know about this system? Where do I go from here? And what about the bogus reading on fan1? And how about the boundaries, can I be certain that they are correct for my system? How do I get ksim, or any other hardware monitoring client working? Basically I am an estatic hardware monitoring clueless dude, and need a little help. Rob -- Linux: For the people, by the people.