On Tue, Jul 12, 2011 at 11:25 AM, Jonathan Guyer <gu...@nist.gov> wrote:
>
>
> On Jul 12, 2011, at 10:54 AM, Marc Saudreau wrote:
>
>> Whatever the case, when I try to impose a fixed value, the temperature of
>> faces is not uniform. I guess I should have the same value on all faces I
>> fixed the temperature ! See the attached jpg file when temperature is fixed
>> on the lateral surface.
>
> The visualization is of the temperature of the cell centers and so I would 
> expect some fluctuations as the cell centers don't all lie at the same 
> radius. Nonetheless, you seem to have variations of a degree or more on the 
> cells bordering the exterior, which does seem a bit much. Maybe Wheeler knows 
> if it would be feasible/beneficial to switch to the DiffusionTerm with 
> corrections once a converged solution is obtained with 
> DiffusionTermNoCorrection.

Mixing DiffusionTermNoCorrection and DiffusionTerm won't help, but I a
not sure that there is a problem with the solution anyway.

-- 
Daniel Wheeler