On Thu, Dec 6, 2012 at 5:21 PM, Adam Stone <arstone...@gmail.com> wrote:
> > > > > and the intensity profile is a Gaussian beam: > > > > Adam, I assume this source is highly concentrated at the centre of your domain. One thing you could try is integrating I explicitly and then taking the cell volume average and using that as the source. This may give a much better result on a coarse grid. Use \frac{\int I dV}{\int dV} as the source rather than simply I. Just a suggestion, not entirely sure that this is the issue. -- Daniel Wheeler
<<dcjdffei.png>>
_______________________________________________ fipy mailing list fipy@nist.gov http://www.ctcms.nist.gov/fipy [ NIST internal ONLY: https://email.nist.gov/mailman/listinfo/fipy ]