On Fri, 29 Sep 2000, Scott Fendley wrote:
> allocate funds to get a more robust system to be the production FW.) I
> have 4 3com 3c905b and 3c905's, an SMC Etherpower combo card, and an SMC
> 10/100 card that I have used in this system. However I have been unable
> to get traffic to make it across the bridge. This leads me to believe it
> is a configuration under FreeBSD or with the drawbridge that is preventing
> this to work.
>
> Additionally, when using 2 3com cards, I get the following error on
> console. "xl1: Watchdog timeout." While using the SMCs, I get this
> message.... "tx0: device timeout X packets, seems we can continue
> normaly"
This sounds like an IRQ issue. Do this `/sbin/dmesg | grep irq`. Anything
look the same ? If yes, that is the problem. Check the link lights as well
on the hub/switch or on the back of your NICs.
cheers,
.truman.
-
[To unsubscribe, send mail to [EMAIL PROTECTED] with
"unsubscribe firewalls" in the body of the message.]