Scott Fendley wrote:
>
> have 4 3com 3c905b and 3c905's, an SMC Etherpower combo card, and an SMC
> 10/100 card that I have used in this system. However I have been unable
> to get traffic to make it across the bridge. This leads me to believe it
> is a configuration under FreeBSD or with the drawbridge that is preventing
> this to work.
>
> Additionally, when using 2 3com cards, I get the following error on
> console. "xl1: Watchdog timeout." While using the SMCs, I get this
> message.... "tx0: device timeout X packets, seems we can continue
> normaly"
>
I had a similar problem with very similar hardware.
The problem turned our to be an IRQ conflict with the BIOS watchdogtimer
and the 3com card.
Hugh.
-
[To unsubscribe, send mail to [EMAIL PROTECTED] with
"unsubscribe firewalls" in the body of the message.]