[EMAIL PROTECTED] wrote: > Dave, > > I use my Elecraft XG-1 at 50uV to do the RX level calibration (this > corresponds to -73dBm which is S9). > I use either the XG-1 or wwv at 10.0MHz for the RX freq calibration. > As pointed out earlier, the RX null requires a stronger sig than the > 50uV supplied by the XG-1 so a second TX is a good choice for this > calibration. > > Your situation with the noise floor so low sounds like something isn't > right with the level cal. My noise floor typically sits at about > -130dBm on 20m with med pre-amp setting. It sounds like you need to > recalibrate the RX level against a known sig level, if I'm reading your > comments correctly. > > Pete, N3EVL
I think I've been confusing old instructions, and the latest instructions... OK, all reset, PA set up again, and the RX level reset to -70dBm. I'm listening to the Russian frequency standard on 9.996MHz. Which is peaking somewhere about -120dB above noise, which is at about -140dB on the standard setting. Unfortunately, WWV isn't so good now, it being night over here. LOL. Ah well, maybe tomorrow... _______________________________________________ FlexRadio mailing list FlexRadio@flex-radio.biz http://mail.flex-radio.biz/mailman/listinfo/flexradio_flex-radio.biz Archive Link: http://www.mail-archive.com/flexradio%40flex-radio.biz/ FlexRadio Homepage: http://www.flex-radio.com