"Klaus Lohmann" <[EMAIL PROTECTED]> schrieb: Eric,a few weeks ago I asked you to provide a software version to me which allows me to go below 38.0dB in the calibration routine table. Maybe I have missed your answer but I found out myself that 38.0dB is already the lower limit: at this level we have full drive from the 4-stack board.Therefore - please - provide me with information what 38.0dB really means: the lower the figure the higher the output. When asked by customers I would like to feel more comfortable.Maybe it would be a good idea to make it clear in the table itself: 0dB is maximum and then -xxdB as appropriate on the bands.Gerald, John, I still have problems with 2 units from customers to get full output (100W) on 10m (13.8V at the terminal)- I get 90 Watts maximum even after installing the MICA cap on T2. The PA cal. routine is passed but our specs tell the customers 100W on all HF bands ...Both units are RoHS and deliver on the higher HF-bands significantly less than 1000mW (10m 500mW only). Will report more on that later.Klaus -------------- next part -------------- An HTML attachment was scrubbed... URL: http://mail.flex-radio.biz/pipermail/flexradio_flex-radio.biz/attachments/20070206/9293ab93/attachment.html _______________________________________________ FlexRadio mailing list [email protected] http://mail.flex-radio.biz/mailman/listinfo/flexradio_flex-radio.biz Archive Link: http://www.mail-archive.com/flexradio%40flex-radio.biz/ FlexRadio Homepage: http://www.flex-radio.com/
FlexRadio Knowledge Base: http://kb.flex-radio.com/