On Saturday, 10 April 1999 at  4:05:10 +0200, Michael Reifenberger wrote:
> On Sat, 10 Apr 1999, Greg Lehey wrote:
>>> The panic occurs only, if I first use the incorrect config file with
>>> 'stripe', then the corrected one with 'striped' and then detaching
>>> the plex and the subdisks.
>
> This point is still valid.

In fact, it's not necessary.  It happens any time you detach the last
subdisk from a striped or RAID-5 plex.

> # vinum detach raid.p0
> # vinum detach raid.p0.s0
> # vinum detach raid.p0.s1
> ..panic..
>
> It seems to be important to remove the last stale subdisk.

Correct.  What happened to the stack traces?  Don't bother, though,
I've reproduced it here.  Expect a fix in a couple of hours.

Greg
--