Mike J wrote:
> I've fixed the x86 module (was using a wrong client config file). So I
> have x86 working but don't have the ppc module working.
..
> Is this likely the cause of my issue?  

  Yes.  Figure out how to build the MD5 code with the correct endian
definitions.  Don't be afraid to hard-code the definition in the source.

  Alan DeKok.
-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html