Hi Jon,
are the ventricles labeled properly in the aseg? Probably not. Try
running recon-all with -bigventricles and see if it improves.
cheers,
Bruce
On Mon, 7 Jan
2008 [EMAIL PROTECTED] wrote:
We are having trouble posteriorly with delineating the pial and white matter
surfaces in scans with lots of atrophy. I include 2 pictures which highlight
the problem. We would greatly appreciate your opinion on dealing with this.
best wishes
Jon
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer