Yes, my data have been normalized to the MNI space. So, in my case, what should
I do if I want to use the mri_surf2vol function?
Best,
Feng
发件人:Douglas Greve <gr...@nmr.mgh.harvard.edu>
发送时间:2015-09-29 00:00
主题:Re: [Freesurfer] Question about the volume conversion in freesurfer
收件人:"freesurfer"<freesurfer@nmr.mgh.harvard.edu>
抄送:
This is not an easy thing to do. First of all, did you apply a nonlinear
registration to get the fMRI to the normalized MNI space? If so, then you can
not do what you want with the data you have pre-processed.
On 9/24/15 2:26 AM, chenhf_uestc wrote:
Dear freesurfer experts,
I want to compute functional connectivity based on the region with
significantly different cortical thickness of two groups. The fMRI data have
been preprocessed by using SPM software and normalized to the MNI space.
However, I do not how to use the function mri_surf2vol.
The required flagged arguments include --surfva, --hemi and --volreg (i.e.,
volume registration file). How can I set up the --volreg argument? What is the
third arguments --volreg? The online manual states that contains the matrix
that maps XYZ in the reference anatomical to XYZ in the functional volume. The
format of this file is that as output by tkregister2 and includes the name of
the subject. It will be assumed that the input surface values are sampled on
the surface of this subject.
Where could I find the volume registration file?
Any help would be greatly appreciately.
Best,
Feng
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.