Hi John,

you should check if the number of time points per subject is relatively random 
across your two patient groups. You don’t want a bias, let’s say one patient 
group with 2 tp and the other with 3.

You can compare the atrophy across these two groups easily with LME. Or you can 
also test if the rate is different from zero in each individual group. 

You will never be able to compute atrophy rates for your control group (as you 
only have a single time point for them) so you cannot compare with them either.

Best, Martin


> On Jan 28, 2016, at 12:23 PM, John Anderson <j.ander...@publicist.com> wrote:
> 
> Hi Dr Martin,
> I have two groups of patients and one group of controls.
> The patients scanned multiple times but the number of time points is 
> different between the subjects.
> The controls have only one time point.
>  
> I aim to :
> 1. I wanted to study the changes in cortical thickness over time in each 
> group of patients.
> 2. I wanted to compare the change in cortical thickness between patients and 
> controls over time.
>  
> I followed wiki and I choose LME to run the analysis.
> My questions are:
> 1. Can I use mass univariate analysis to check the changes in cortical 
> thickness over time in only one group of patients. The example In wiki was 
> for four groups.
> 2. Can I do a comparison in cortical thickness over time between controls ( 
> who have  only one time point ) and patients using mass univariate approach.
>  
> Bests,
> John 
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.